If you are shopping for Ethernet cable and one box costs a fraction of the other, the difference is usually what is inside the conductor. A lot of discount “CAT6” is CCA — copper-clad aluminum — which is an aluminum conductor with a thin copper coating on the outside. It will look and feel correct in your hand, and it will quietly cause problems once it is powering cameras inside a wall.
What CCA cable actually is
CCA stands for copper-clad aluminum. The core of each conductor is aluminum, and a microscopically thin layer of copper is bonded around the outside. Because every visible surface is copper, the cable passes the test most people apply at the counter: it looks like copper, the jacket says CAT6, and the connector crimps onto it normally.
The giveaway is underneath. Aluminum carries roughly 55% more electrical resistance than pure copper. That single difference is what drives everything else that goes wrong with it, and none of it is visible until the cable is already pulled, terminated and buried behind drywall.
Why CCA struggles with Power over Ethernet
A security camera is not just sending data down that cable. It is also drawing its power through it, over PoE. Resistance in the conductor works against both jobs at once.
First, the cable heats up under load. Higher resistance means more of the electrical energy you are pushing down the run turns into heat instead of arriving at the camera. Second, voltage drops along the length of the run. The further the camera is from the switch, the less of the supply voltage actually reaches it.
That is why CCA problems tend to look random rather than obvious. The cameras closest to the rack behave perfectly. The ones at the far end of a building are the ones that reboot, drop offline for a few seconds, or go down when infrared kicks in at night and the current draw rises. People chase the camera, swap the camera, and the cable is never suspected.
Why it breaks during installation
Aluminum is brittle compared with copper. Bend a CCA conductor around a tight corner, or drag it through conduit, and the metal inside the jacket can crack or snap outright. The jacket keeps its shape, so nothing looks wrong from the outside.
A cracked conductor often still passes a quick visual check and even an initial commissioning test. It shows up weeks later as an open pair, or as a link that only fails when the cable warms, moves, or has to carry more current. On a single-camera job that is an afternoon of frustration. On a forty-camera job it is weeks of intermittent faults with no clear cause.
How to tell what you have before it goes in the wall
Three checks will catch almost all of it:
- Read the jacket print. If it says CCA anywhere, that is your answer, regardless of what the box says.
- Ask for the spec sheet before you order, not after delivery. If the conductor is not stated as 100% pure bare solid copper, treat the cable as suspect.
- Scrape a conductor. Strip a bit of jacket and gently scrape one wire with a knife. Solid copper stays copper-coloured all the way through. If silver shows underneath the scratch, it is copper-clad aluminum.
What we recommend for homes and businesses in Cambridge, Kitchener, Waterloo, Brantford and Hamilton
We specify 100% pure bare solid copper on every camera install, and there are local reasons beyond the general ones.
Long runs are normal here. Rural and semi-rural properties around Cambridge, Brantford and the townships often have detached garages, barns, shops and driveway poles a long way from the house, and those are exactly the runs where voltage drop decides whether a camera stays up. Warehouse and shop installs around Hamilton and the Kitchener industrial parks have the same issue across a long floorplate.
Temperature matters too. Cable in an unheated garage, a barn, a soffit or an attic swings between extremes through an Ontario winter and summer. Metal that is already brittle does not enjoy that cycle, and connections made in cold weather are exactly where a cracked CCA conductor shows itself.
Older housing stock across Kitchener, Waterloo and Hamilton adds the last reason. Fishing cable through old walls, balloon framing and tight joist bays means sharp bends and hard pulls. That is the handling CCA is worst at, and in a finished older home re-pulling a failed run is far more expensive than the cable ever was.
FAQ
Is CCA cable ever acceptable?
For a professional CCTV install, we do not use it. The savings on a box of cable are small compared with the cost of returning to a finished ceiling or wall to re-pull a run, and PoE cameras are the application that punishes resistance hardest.
My cameras already work on cheap cable — am I fine?
Possibly, for now. CCA problems usually appear later or seasonally: a camera that drops out at night, in the heat, or after someone disturbs a cable tray. If you have a camera that is “sometimes offline” and nobody can reproduce it, the cable is worth checking.
How do I check cable that is already installed?
Look at the jacket print where it enters the rack or the camera, and check any offcut you still have with the scrape test. If you are not sure, send us a photo of the jacket print and the box label and we will tell you what you are looking at.
If you are planning a camera system, or trying to work out why the cameras at the far end of your property keep dropping, we offer a free site survey across Cambridge, Kitchener, Waterloo, Brantford and Hamilton. Call us at 226-227-7966 or get in touch at spyonsecurity.com/contact.